USGS - science for a changing world

Open-File Report 02-227

Multielement Geochemical Dataset of Surficial Materials for the Northern Great Basin


Metadata for ngb.xls and ngb.csv

ID

Unique identifier (primary key) assigned by the authors of this paper.

SAMPID

Non-unique sample number assigned by the collecting laboratory.

SAMPTYP

Sample type; indicates the sample source, medium, and/or treatment. Unless otherwise noted, samples were collected and treated under the NURE HSSR program. See Data Quality: Sample Media for an in-depth discussion of sample types.

STUDY

Name of the mineral-resource study under which the sample was analyzed.

QUAD

Name of the 1° x 2° USGS quadrangle in which the sample was collected.

LONGITUDE

Longitude, in decimal degrees, of the sample site. Negative numbers indicate west longitudes. These values are assumed to be based upon the NAD27 Datum and Clarke 1866 Ellipsoid. Sample-site locations recorded by ORGDP commonly give values with 3 decimal places instead of the more common usage of 4 decimal places; therefore, the possible error of location is ±183 feet or ±55 meters.

LATITUDE

Latitude, in decimal degrees, of the sample site. Positive numbers indicate north latitudes. These values are assumed to be based upon the NAD27 Datum and Clarke 1866 Ellipsoid. Sample-site locations recorded by ORGDP commonly give values with 3 decimal places instead of the more common usage of 4 decimal places; therefore, the possible error of location is ±183 feet or ±55 meters.

Ag(tot)_ppm

Elemental concentration of silver in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Ag(part)_ppm

Elemental concentration of silver in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Al_%

Elemental concentration of aluminum in percent, analyzed by the ICP-40 method (Briggs, 1996).

As(tot)_ppm

Elemental concentration of arsenic in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

As(part)_ppm

Elemental concentration of arsenic in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Au_AA

Elemental concentration of gold in parts per million, analyzed by graphite furnace atomic adsorption (O'Leary and Meier, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Ba_ppm

Elemental concentration of barium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Be_ppm

Elemental concentration of beryllium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Bi(part)_ppm

Elemental concentration of bismuth in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Ca_%

Elemental concentration of calcium in percent, analyzed by the ICP-40 method (Briggs, 1996).

Cd(tot)_pm

Elemental concentration of cadmium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Cd(part)_ppm

Elemental concentration of cadmium in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Ce_ppm

Elemental concentration of cerium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Co_ppm

Elemental concentration of cobalt in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Cr_ppm

Elemental concentration of chromium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Cu(tot)_ppm

Elemental concentration of copper in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Cu(part)_ppm

Elemental concentration of copper in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Fe_%

Elemental concentration of iron in percent, analyzed by the ICP-40 method (Briggs, 1996).

Ga_ppm

Elemental concentration of gallium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

K_%

Elemental concentration of potassium in percent, analyzed by the ICP-40 method (Briggs, 1996).

La_ppm

Elemental concentration of lanthanum in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Li_ppm

Elemental concentration of lithium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Mg_%

Elemental concentration of magnesium in percent, analyzed by the ICP-40 method (Briggs, 1996).

Mn_ppm

Elemental concentration of manganese in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Mo(tot)_ppm

Elemental concentration of molybdenum in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Mo(part)_ppm

Elemental concentration of molybdenum in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Na_%

Elemental concentration of sodium in percent, analyzed by the ICP-40 method (Briggs, 1996).

Nb_ppm

Elemental concentration of niobium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Ni_ppm

Elemental concentration of nickel in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

P_%

Elemental concentration of phosphorus in percent, analyzed by the ICP-40 method (Briggs, 1996).

Pb(tot)_ppm

Elemental concentration of lead in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Pb(part)_ppm

Elemental concentration of lead in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Sb(part)_ppm

Elemental concentration of antimony in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

Sc_ppm

Elemental concentration of scandium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Sn_ppm

Elemental concentration of tin in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Sr_ppm

Elemental concentration of strontium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Th_ppm

Elemental concentration of thorium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Ti_%

Elemental concentration of titanium in percent, analyzed by the ICP-40 method (Briggs, 1996).

V_ppm

Elemental concentration of vanadium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Y_ppm

Elemental concentration of yttrium in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Zn(tot)_ppm

Elemental concentration of zinc in parts per million, analyzed by the ICP-40 method (Briggs, 1996).

Zn(part)_ppm

Elemental concentration of zinc in parts per million, analyzed by the ICP-Partial method (Motooka, 1996). (ND = not determined, and indicates samples where there was insufficient material to perform ICP-partial analysis; B = no analytical value was reported, most commonly because of inter-element interferences.)

CLICK HERE to access References.

Return to the main page.

 

Accessibility FOIA Privacy Policies and Notices

Take Pride in America logo USA.gov logo U.S. Department of the Interior | U.S. Geological Survey
URL: http://pubsdata.usgs.gov/pubs/of/2002/0227/metadata.html
Page Contact Information: GS Pubs Web Contact
Page Last Modified: Wednesday, 07-Dec-2016 19:26:47 EST